Outlook 2003 SP2 - 11.6568.6568 Outlook 2007 RTM - 12.4518.1014 Outlook 2010 RTM 14.0.4760.1000 in .NET Assign Code 3/9 in .NET Outlook 2003 SP2 - 11.6568.6568 Outlook 2007 RTM - 12.4518.1014 Outlook 2010 RTM 14.0.4760.1000




How to generate, print barcode using .NET, Java sdk library control with example project source code free download:
Outlook 2003 SP2 - 11.6568.6568 Outlook 2007 RTM - 12.4518.1014 Outlook 2010 RTM 14.0.4760.1000 using barcode writer for .net vs 2010 control to generate, create barcode code39 image in .net vs 2010 applications. .NET Framework The Major build numb barcode 3 of 9 for .NET ers are consistent across the entire Office suite and never change. For example, for Office 2003 the Build number is 11, for Office 2007 the Build number is 12, and for Office 2010 the Build number is 14.

. Managing Client Acce ss The Minor and Build numbers will change depending on the hotfixes and service packs deployed to the clients. Therefore, the -MAPIBlockOutlookVersions parameter will accept a range of values that will allow you to be very specific about which versions should be blocked. You can even specify multiple version ranges and separate each one using a semi-colon.

For example, the following command can be used to block access to Exchange for all versions of Outlook below 2007 and 2010:. Set-CASMailbox dsmit visual .net Code 39 h -MAPIBlockOutlookVersions "-5.9.

9;7.0.0-11.

9.9". As you can see here, we"ve specified two values. The first value indicates that any client version below 5.9.

9 will be unable to connect to this mailbox. The second value specifies a range from 7 to 11.9.

9 which effectively blocks all access to any client versioned lower than 12.x.x, except for those versioned at 6.

x.x. This allows only Outlook 2007 and 2010 clients to connect to this mailbox.

It also allows Exchange server MAPI connections from other servers, identified using 6.x.x version numbers.

Keep in mind that when you are making these changes they will not take effect right away. If you want to force this change so it is effective immediately, restart the RPC Client Access service on the CAS server used to access the mailbox. Make sure to do this outside of production hours as it will knock every user connected to that CAS server offline.

. There"s more In addition to block ing Outlook versions at the mailbox level, we can also block them at the server level. Since the MAPI client endpoint is now at the CAS role for mailbox access, we can use the Set-RPCClientAccess cmdlet to accomplish this..

Set-RpcClientAccess Code 39 Extended for .NET -Server cas1 ` -BlockedClientVersions "-5.9.

9;7.0.0-13.

9.9". You can see here tha t we use the BlockedClientVersions parameter to define the client versions that should be blocked, and it works in exactly the same way as it does when using the Set-CASMailbox cmdlet. In this example, all client versions below Outlook 2010, with the exception of client versions 6.x.

x, will be blocked at the CAS server level. Notice that the server name has been specified with this command and you"ll need to run it against each CAS server that should block specific Outlook versions..

Reporting on active OWA and RPC connections One of the nice thin gs about using PowerShell to manage Exchange is that you have a great deal of flexibility when it comes to solving problems. When the Exchange Management Shell does not provide a cmdlet that specifically meets your needs, you can often tap into other. 7 . resources accessible through PowerShell. This recipe provides a great example for this. In this section, we"ll use PowerShell to query performance counter data to determine the number of active OWA and RPC connections on one or more CAS servers.

. How to do it... 1. To determine the number of users currently logged into OWA on a CAS server, use the following command syntax:. Get-Counter Counter Code39 for .NET "\\cas1\MSExchange OWA\Current Users". This retrieves the t otal number of users logged into OWA on the CAS1 server. The output from this command will look similar to the following:. Timestamp --------11 barcode 3/9 for .NET /30/2010 11:57:59 AM CounterSamples -------------\\cas1\msexchange owa\current users : 4. Viewing the output, we can see that four users are currently logged on to OWA. 2. To find the total number of RPC connections, we simply need to use another performance counter:.

Get-Counter "\\cas1\ visual .net Code 39 Extended MSExchange RpcClientAccess\User Count". Similar to the previous example, the total number of RPC connects will be reported. How it works... The Get-Counter cmdl et is a PowerShell v2 core cmdlet that allows you to retrieve performance counter data from both local and remote machines. In the previous example, we collected the total of current OWA users using the \MSExchange OWA\Current Users counter and the total number of RPC connections using the MSExchange RpcClientAccess\User Count counter on the CAS1 server. In both of these examples, we"ve specified the computer name in the counter name assigned to the -Counter parameter.

Another way to gather performance counter data from a remote computer is to use the -ComputerName parameter:.